- Products
Operation:
When de-energized, the valve allows a flow from ② to ①, flow from ① to ② is severely restricted in this mode.
When energized, the valve’s poppet closed on its seat, blocking flow from ② to ①. The cartridge will allow ① to ② flow after overcoming the solenoid force.
Operation of manual override option:
To override, push button in to activate. To return to normal valve function, release button.
Specifications
Max. operating pressure: |
207 bar |
Flow: |
See pressure drop vs. flow graph |
Internal leakage: |
3 Drops/min. max. at 207 bar |
Temperature: |
(-40℃ to +120℃) with NBR material seals |
Coil duty rating: |
Continuous from 85% to 115% of nominal voltage |
Fluids: |
Mineral-based fluids with viscosity of 7.4 to 420 cSt. |
Cavity: |
HY16-2, see page H.1.5 |
Body material: |
Steel & ductile iron rated to 350 bar |