- Products
Operation:
When de-energized, the valve blocks flow in both directions. When energized, the cartridge’s spool shifts to allow flow in both directions.
Operation of manual override option:
To override, push button in to activate. To return to normal valve function, release button.
Specifications
Max. operating pressure: |
250 bar |
Flow: |
See pressure drop vs. flow graph |
Internal leakage: |
5 Drops/min. max. at 250 bar |
Temperature: |
(-40℃ to +120℃) with NBR material seals |
Coil duty rating: |
Continuous from 85% to 115% of nominal voltage |
Fluids: |
Mineral-based fluids with viscosity of 7.4 to 420 cSt. |
Cavity: |
HY08-2, see page H.1.2 |
Body material: |
6061-T6 Aluminum alloy rated to 207 bar, steel & ductile iron rated to 350 bar |