Operation:
When de-energized, the valve flows paths are blocked. When energized, the cartridge’s spool shifts to allow flow ③ to ④, and from ② to ①.
Operation of manual override option:
To override, push button in, twist counterclockwise 180° and release. In this position, the valve will remain detented in the shifted condition. To return to normal operation, push button in, twist clockwise 180° and release. Override will be detented in this position.
Specifications
| 
 Max. operating pressure:  | 
 207 bar  | 
| 
 Flow:  | 
 See pressure drop vs. flow graph  | 
| 
 Internal leakage:  | 
 82 cc/min. max. at 207 bar  | 
| 
 Temperature:  | 
 (-40℃ to +120℃) with NBR material seals  | 
| 
 Coil duty rating:  | 
 Continuous from 85% to 115% of nominal voltage  | 
| 
 Fluids:  | 
 Mineral-based fluids with viscosity of 7.4 to 420 cSt.  | 
| 
 Cavity:  | 
 HY08-4, see page H.1.3  | 
| 
 Body material:  | 
 6061-T6 Aluminum alloy rated to 207 bar, steel & ductile iron rated to 350 bar  | 