- Products
Operation:
When de-energized, the HY-SP-10-20 acts as a check valve, allows flow from ① to ②, while blocking flow from ② to ①. when energized, the cartridge’s poppet lifts to open the ② to ① flow path. Flow is proportional to current applied to the coil. Flow varies with manual override.
Technical specification (for application beyond these parameters, please contact with us)
|
Model |
HY-SP10-20 |
|
Installation position |
Unlimited |
|
Storage temperature (℃) |
-20℃ to +55℃ |
|
Ambient temperature (℃) |
-20℃ to +50℃ |
Hydraulic specification
|
Operating pressure |
250 Bar (3625psi) |
|
Minimum operating dither/ pulse frequency |
70 Hz |
|
Flow |
Up to 68 lpm (18gpm) at 34.5 bar (500psi) |
|
Hydraulic fluid |
Mineral oil, phosphate-ester |
|
Fluids |
7.4 ~ 420 cSt (50 ~ 2000 sus) |
|
Temperature |
-40℃~+120℃, with NBR seals |
|
Cavity |
HY10-2, see page H.1.3 |
|
Internal leakage |
5 Drops/minute max. at 250 bar (3625psi) |
|
Hysteresis |
Less than 5% up to 75% of I-max; Less than 10% above 75% of I-max. |
Electrical specification
|
Max. Control current |
12 VDC coils: 1.0 ± 0.1A; 24 VDC coils: 0.5 ± 0.05A |

English
Español
русский
français
Deutsch





