- Products
Description
A cartridge-style adjustable pressure-compensated flow control valve.
Operation
The valve maintains a constant flow rate from ③ regardless of load pressure changes in the system downstream of HYFR10-30 (Regulator Pressure Compensated Flow Control Valve), or in the bypass leg at ②. The valve will pressure-compensate once a minimum pressure drop (determined by spring adjustment setting) is achieved from ① to ③. This value will range from approximately 4.8 to 13.8 bar (70 to 200 psi). Bypass port ③ may be fully pressurized. The cartridge may be adjusted to ± 25% of nominal setting. At nominal setting, pressure drop is approximately 9 bar (130 psi). Flow out of priority port ③ may vary based on input flow amount, particularly with lower temperatures and increased fluid viscosity.
Specifications
Operating pressure: |
207 Bar |
Flow setting: |
Low range: 1.9 to 9.5 lpm (0.5 to 2.5 gpm) |
Specify in 1.9 lpm (0.5 gpm) increments |
|
High range: 11.4 to 22.7 lpm (3.0 to 6.0 gpm) |
|
Specify in 3.8 lpm (1 gpm) increments |
|
Temperature: |
(-40℃ to +120℃) with NBR material seals |
Fluids: |
Mineral fluids with viscosity of 7.4 to 420 cSt. |
Cavity: |
HY10-3, see page H.1.4 |
Body material: |
6061-T6 Aluminum alloy rated to 207 bar, steel & ductile iron rated to 350 bar |