HYFR10-20F (Regulator Pressure Compensated)

A cartridge-style non-adjustable pressure-compensated flow control valve.

Description

A cartridge-style non-adjustable pressure-compensated flow control valve.

 

Operation

The valve maintains a constant flow rate out of ② regardless of load pressure changes in the circuit downstream of ②. The fixed control orifice is factory preset to customer flow specification. The valve begins to respond to load changes when the flow through the valve creates a pressure differential across the control orifice greater than 5.5 bar, with accurate flow maintenance from 7.6 to 240 bar. Reverse flow (② to ①) returns through the control orifice and is non-compensated.

 

Specifications

Operating pressure:

240 Bar

Flow setting:

0.4 L/min. min. ; 22.7 L/min. max.

Flow maintenance accuracy:

0.37 to 1.85 L/min. settings ± 20%

1.89 to 5.63 L/min. settings ± 15%

5.68 to 22.71 L/min. settings ± 10%

Temperature:

(-40℃ to +120℃) with NBR material seals

Fluids:

Mineral fluids with viscosity of 7.4 to 420 cSt.

Cavity:

HY10-2, see page H.1.3

Body material:

6061-T6 Aluminum alloy rated to 207 bar, steel & ductile iron rated to 350 bar

 