- Products
Description
A cartridge-style non-adjustable pressure-compensated flow control valve.
Operation
The valve maintains a constant flow rate out of ② regardless of load pressure changes in the circuit downstream of ②. The fixed control orifice is factory preset to customer flow specification. The valve begins to respond to load changes when the flow through the valve creates a pressure differential across the control orifice greater than 5.5 bar, with accurate flow maintenance from 7.6 to 240 bar. Reverse flow (② to ①) returns through the control orifice and is non-compensated.
Specifications
Operating pressure: |
240 Bar |
Flow setting: |
0.41 L/min. min. ; 7.5 L/min. max. |
Flow maintenance accuracy: |
0.2 to 1.8L/min. settings ± 15%; 1.9 to 7.5L/min. settings ± 10% |
Temperature: |
(-40℃ to +120℃) with NBR material seals |
Fluids: |
Mineral fluids with viscosity of 7.4 to 420 cSt. |
Cavity: |
HY08-2, see page H.1.2 |
Body material: |
6061-T6 Aluminum alloy rated to 207 bar, steel & ductile iron rated to 350 bar |