- Products
Explosion Isolation Proportional Pilot-operated Relief Valve
Technical specification
Specification |
03 |
06 |
10 |
||
Max. Working pressure (MPa) |
Oil ports A, B, X |
31.5 |
|||
Oil port Y |
0 Mpa return to oil tank |
||||
Working pressure (Mpa) |
7 16 25 31.5 |
||||
Max. flow (L/min) |
200 |
400 |
600 |
||
Working fluid |
Mineral oil; phosphate-ester |
||||
Fluid temp. (℃) |
-20~70 |
||||
Viscosity (mm2/s) |
15~380 |
||||
Hysteresis (%) |
< 2 |
||||
Repeatability (%) |
< 2 |
||||
Linearity (%) |
< 3.5 |
||||
Working voltage (V) |
DC24 |
||||
Rated current (mA) |
750 |
||||
Coil resistance (Ω) |
19.5 |
||||
Insulation grade |
IP55 |
||||
cleanliness |