3 Ways Single Pilot Operated Check Valves, In Line

Use and operation:
These valves are used to block the cylinder in one direction.
The flow is free in one direction and blocked in the reverse
direction until pilot pressure is applied.

Applications:
Connect V to the pressure flow, C to the actuator’s side you
want the flow to be blocked and Pil. to to the pilot line.

Technical specification:

Specification

1/4”

3/8”

1/2”

3/4”

Pilot ratio

1:9.8

1:6.5

1:4.6

1:4.4

Max flow (L/min)

15

30

45

80

Max pressure (Bar)

350

300

300

250

Cracking Pressure (Bar)

2.5

5

3

0.5

 

See more...